Simplified 2D thermal simulations of a 3D geometry
Sixense necs studied the thermal behaviour of a tunnel exposed to fire. Gigogene models. Kilometre tunnel (confidential), Decametre zone (see figure on left), Decimetre element (see figure on right).
Parametric study of the local overshoot of a critical temperature as a function of fire properties, materials and local configuration. Simplified 2D thermal simulations of a 3D geometry.