Project : Study of a nuclear reactor with consideration of inter-building joints
Mission : Our design office took over existing design notes and checked the quality of the design data.
After verification Sixense necs developed the strategy for incorporating the seals into the existing models.
Following this, we modified the study and simulation files with the conversion of the Hercules model into Code_Aster.
Finally, our engineers carried out non-linear spectral analyses on a modal basis, taking into account the clash between buildings.