Columns made of Ductal® (high performance concrete) – MuCEM (Musée des Civilisations de l’Europe et de la Méditerranée)
Behaviour of the reinforced concrete structures up to failure – Non linear time history thermal analysis – Concrete damage and steel yielding assessment due to the effects of temperature (Eurocode 2/1-2)
Verification of numerical modellings
Conversion of file formats – Comparison with drawings – Verification of modelling hypothesis – Comparison of results
ITER (Fusion for Energy) – Controller (APAVE) – Main constructor (ENGAGE)
Verification of the design modelling, check of the computed forces and of the reinforcement design.
Simplified 2D thermal analysis of a 3D geometry
Thermal behaviour of a tunnel exposed to fire. Parametric study of local excess of a critical temperature according to the fire properties, the materials and the locale configuration. Simplified 2D thermal analysis of a 3D geometry.
Assessment of the resistance of the SANDIA II containment mock up
Read moreFree fall of a container on reinforced concrete structure
Definition of the critical free fall scenario. Modelling of the dropping loads and the target : steel container, shock absorber made of organic material, reinforced concrete structure covered by a steel cap or a radio protection slab. Presence of steel items on the free fall path able to absorb some of the fall energy.
Case of a collapsing slab during earthquake
Definition of the failure scenario of the roof made of precast slab elements and post tensionned beams. Modelling of the dropping items and of the container. Dynamic analysis of the impact between these items and the steel container and assessment of the damage.
Impact assessment and comparison of the calculation methodologies with the use of several finite element calculation softwares
Read more